Electrical Rating | AC/DC28V-1A |
Withstand Voltage | 500VAC for 1min |
Contact life | 1,000,000 times activation or more (Tested with relay 24V-0.3A Load) |
Insulation resistance | 100MΩor more (500VDCMegger) |
Contact resistance | 1.0 Ω or less (If under operating force or more) |
Operating temperature range | -10℃~+60℃ |
Withstand load | 1470N (Under φ100 pressing plate for 1 min) |
Ingress protection | Drip proof (IP54 equivalent) |
Supplied Cable | VFF0.75m㎡X 2-wireX0.5m(Standard) ※Changeable |
Operating force | 13N approx. (under φ15 pressing plate) |
Weight | 950g/m |
Circuitry | 1a |
Inactive area | Approx 25~30mm on both ends |
Color | Black |
Overtravel | Approx 25mm |
Material of rubber | TPE |
Material of end caps | CR (Option) |
Extra waterproof | Available (Option) |
Sensing edge serves as an effective means of prevention of getting caught in automated machines, and also be used for emergency stop of medical equipment, collision detection of AGV etc.
Large size edge
Instantaneous activation type
High sensitivity for fastest activation with substantial overtravel for maximum cushioning
Maximum length of material
Rubber(2400mm)/Aluminum channel (2400mm)
In case of needing longer length , please joint the multiple channels
【Explanation of type】
OT-TS47F L = ●● (Length of tape switch)
2-wire or 4-wire(One lead from each end or Both leads from one end)
Lead wire ● m (Length of lead wire)
※In case of non instruction, 2 wireX500mm will be.
【Optional item】
Angle channel
End caps
Fail-safe controller (Only 4-wire type can be used)
- Drawings
- Circuit diagram
- Other image 3
- Other image 4
Option
【Fail-safe controller】
- ●4 wire type circuit control unit (Cable disconnection or short circuit detector)
- ●Improve plant safety
- ●4 wire type circuit control unit (Cable disconnection or short circuit detector)
- ●Standards certified product
- ●CE Marking product
- ●Safety Grade: Type 3
- ●High accuracy safety double coil installed