OT-80P
Color:R(Red)
Electrical Rating | AC/DC28V-1A |
Withstand Voltage | 500VAC for 1min |
Contact life | 1,000,000 times activation or more (Tested with relay 24V-0.3A Load) |
Insulation resistance | 100MΩor more (500VDCMegger) |
Contact resistance | 1.0 Ω or less (If under operating force or more) |
Operating temperature range | -10℃~+60℃ |
Withstand load | 1470N (Under φ100 pressing plate for 1 min) |
Ingress protection | Drip proof (IP54 equivalent) |
Supplied Cable | VFF0.5m㎡X 2-wireX0.5m(Standard) ※Only length of wire is changeable |
Operating force | 2.2N approx. (under φ15 pressing plate) |
Weight | 60g/m |
Circuitry | 1a |
Inactive area | Both terminal (Approx 20mm) as well as other areas (Approx 14mm between 35-40mm each) |
Color | Red |
Extra waterproof | Available (Option) |
Mainly have been used for safety measure of FA related devices.
Supporting safety and security in all situations, and application is limitless depending on your idea.。
2-way activation (in response to bending at 10~15 or pressing)
Radius bending is not available
【Explanation of type】
OT-80P-R L = ●● (Length of tape switch) ※Maximum length:3M
2-wire or 4-wire
Lead wire ● m (Length of lead wire)
※In case of non instruction, 2 wireX500mm will be.
【Optional item】
Fail-safe controller (Only 4-wire type can be used)
- Drawings
- Circuit diagram
- Other image 1
- Other image 2
Option
【Fail-safe controller】
- ●4 wire type circuit control unit (Cable disconnection or short circuit detector)
- ●Improve plant safety
- ●4 wire type circuit control unit (Cable disconnection or short circuit detector)
- ●Standards certified product
- ●CE Marking product
- ●Safety Grade: Type 3
- ●High accuracy safety double coil installed