OT-02B
Color:Y(Yellow)、B(Black)

I2013071000201.jpg
Electrical Rating AC/DC28V-1A
Withstand Voltage 500VAC for 1min
Contact life 1,000,000 times activation or more (Tested with relay 24V-0.3A Load)
Insulation resistance 100MΩor more (500VDCMegger)
Contact resistance 1.0 Ω or less (If under operating force or more)
Operating temperature range -10℃~+60℃
Withstand load 1470N (Under φ100 pressing plate for 1 min)
Ingress protection Drip proof (IP54 equivalent)
Supplied Cable VFF0.75m㎡X 2-wireX0.5m(Standard)
※Changeable
Operating force 12N approx. (under φ15 pressing plate)
Weight 100g/m
Circuitry 1a
Inactive area Approx 25mm on both ends
Color Yellow or Black
Extra waterproof Available (Option)
Applicable mounting channel OC-06 (Option)

Mainly have been used for safety measure of FA related devices.
Supporting safety and security in all situations, and application is limitless depending on your idea.。

High sensitivity

Bending Radius:R50

【Explanation of type】
OT-02B-(Y or B) L = ●● (Length of tape switch)
2-wire or 4-wire
Lead wire ● m (Length of lead wire)
※In case of non instruction, 2 wireX500mm will be.

【Optional item】
Fail-safe controller (Only 4-wire type can be used)

Drawings
I2013071000202.jpg
Circuit diagram
I2013071000203.jpg
Other image 1
I2013071000206.jpg
Other image 2
I2013071000207.jpg

Option

【Mounting channel】

  • For mounting tape switches (P4)
  • ●OC-04(Applicable type: OT-41BP, TS3F)
  • ●OC-06(Applicable type: OT-02A, 02B)
  • ◆Maximum length: Up to 2M
    (For 2M over channel, join the multiple channels)
  • ◆Long channel may be shipped in parts

加工について

Mounting method of channel

  • ①Process a mounting hole (for M3 to M4 screws), and screw it in place.
  • ②Use a double-sided tape for fixing is possible, then insert the tape switch after fixing.

断面図

【Fail-safe controller】

SC-2(AC only)

  • ●4 wire type circuit control unit (Cable disconnection or short circuit detector)
  • ●Improve plant safety

PRSU-4

  • ●4 wire type circuit control unit (Cable disconnection or short circuit detector)
  • ●Standards certified product
  • ●CE Marking product
  • ●Safety Grade: Type 3
  • ●High accuracy safety double coil installed

Top of Page