OT-02A-GY
Color:GY(Gray)
Electrical Rating | AC/DC28V-1A |
Withstand Voltage | 500VAC for 1min |
Contact life | 1,000,000 times activation or more (Tested with relay 24V-0.3A Load) |
Insulation resistance | 100MΩor more (500VDCMegger) |
Contact resistance | 1.0 Ω or less (If under operating force or more) |
Operating temperature range | -10℃~+60℃ |
Withstand load | 1470N (Under φ100 pressing plate for 1 min) |
Ingress protection | Drip proof (IP54 equivalent) |
Supplied Cable | VFF0.75m㎡X 2-wireX0.5m(Standard) ※Changeable |
Operating force | 30N approx. (under φ15 pressing plate) |
Weight | 110g/m |
Circuitry | 1a |
Inactive area | Approx 25mm on both ends |
Color | Gray |
Extra waterproof | Available (Option) |
Applicable mounting channel | OC-06 (Option) |
Mainly have been used for safety measure of FA related devices.
Supporting safety and security in all situations, and application is limitless depending on your idea.。
High operating force (recovery)
Bending Radius:R50
【Explanation of type】
OT-02A-GY L = ●● (Length of tape switch)
2-wire or 4-wire
Lead wire ● m (Length of lead wire)
※In case of non instruction, 2 wireX500mm will be.
【Optional item】
Fail-safe controller (Only 4-wire type can be used)
- Drawings
- Circuit diagram
- Other image 1
- Other image 2
Option
【Mounting channel】
- For mounting tape switches (P4)
- ●OC-04(Applicable type: OT-41BP, TS3F)
- ●OC-06(Applicable type: OT-02A, 02B)
- ◆Maximum length: Up to 2M
(For 2M over channel, join the multiple channels) - ◆Long channel may be shipped in parts
Mounting method of channel
- ①Process a mounting hole (for M3 to M4 screws), and screw it in place.
- ②Use a double-sided tape for fixing is possible, then insert the tape switch after fixing.
【Fail-safe controller】
- ●4 wire type circuit control unit (Cable disconnection or short circuit detector)
- ●Improve plant safety
- ●4 wire type circuit control unit (Cable disconnection or short circuit detector)
- ●Standards certified product
- ●CE Marking product
- ●Safety Grade: Type 3
- ●High accuracy safety double coil installed